Data Logger Suite: Logging and Monitoring
MODBUS to database: Write MODBUS RTU/TCP values to a database
If you want to write data to a database other than MSSQL or MySQL described in the "Write MODBUS to MSSQL" or "Write MODBUS to MySQL" sections, you have the following options:
1. If there is an ODBC driver for this database, the configuration process is similar to that described in the "Write MODBUS to MSSQL" or "Write MODBUS to MySQL" sections. You will only have to create a table complying with the syntax of your database. For example, the Microsoft Access ODBC drivers come together with the operating system starting from Windows XP, and you can use the Microsoft Access visual development tools to create a database;
2. Suppose it is an SQLBase, Oracle, SQLServer, Sybase, DB2, Informix, Interbase, Firebird, MySQL, or PostgreSQL database. In this case, you can use the "SQL Database Pro" data export plugin (fig.1) instead of the "ODBC database" plugin. You should download and install this plugin separately after you install the program. In this case, you also add MODBUS values and select the parser, but you configure the "SQL Database Pro" plugin instead of the "ODBC database" plugin the way it is described in the manual on our website.
Fig. 1 Selecting the data export plugin
Related articles:
MODBUS RTU, MODBUS ASCII, MODBUS/TCP
- MODBUS power meter data logging (easy method)
- Sunspec-compatible MODBUS power meters, inverters (easy method)
- MODBUS RTU/TCP polling: Configuring master station (MODBUS RTU, MODBUS TCP, requests, response items).
- MODBUS poll: How to make sure that the application sends requests and receives responses?
- MODBUS poll: How to view register values, not raw MODBUS packets?
- MODBUS polling: How to make sure that the application correctly interprets the responses received from the device?
- MODBUS polling: How to view MODBUS register values in a more easy-to-grasp form (graphs, indicators, etc.)?
- MODBUS: How to combine the data of two requests?
- MODBUS: What is the right way to poll multiple devices?
- Copy settings from Simply MODBUS RTU Master to our Modbus Data Logger.
- Copy settings from the MODBUS Poll utility.
- Controlling PLC coil registers status using MODBUS TCP (MODBUS data parser, custom scripts, events generating, and handling).
- MODBUS to MSSQL: Write MODBUS registers to separate columns
- MODBUS to MySQL: Write MODBUS values to the MySQL database
- MODBUS to a database: Writing MODBUS RTU/TCP values to a database
- MODBUS to a database: Write data to two different tables.
- MODBUS to a database: Write data to two different databases, making a complete copy.
- Sentron PAC 3200: MODBUS TCP Data Logging
- Write data to a MODBUS device
- SQL to MODBUS: Send data from a SQL database to MODBUS.
- MODBUS TCP ↔ MODBUS RTU real-time conversion.
BACNET/IP
IEC 62056-21
- IEC 62056-21 power meter data logging (Iskra Emco, Satec, Landis+Gyr)