Changelog of Data Logger Suite - Version History
Fixed issues with user-defined columns ordering and date formats.
Improved data reading in the polling mode for compatible readers.
Now, the interval can be a zero to read data as fast as possible. More on.
Minor bug fixes.
We've fixed a problem with parsing data packets by a timeout. Download.
Now, the module exports date and time values in a custom format as a string.
This prevents Excel from changing the value to the default system format.
We've fixed a rare memory leak when the program works in the service mode with the attached console.
Fixed the "Parent window not found" error in the configuration window. Take a moment and then download it in the Download area.
We've fixed rare memory leaks that can affect all data parser plugins. You can find the update in the Download area.
Some optimizations for small data packets.
This update adds localization in several major languages on the web page, sorting variables in the list, adding variables to the list or table in the desired order.
It resolves the issue with the widget size when resizing the browser window, and the problem with SSL support.
Improved compatibility with 64-bit integer values.
Addressed the problem with Int64 (Large integer) parameters when a value is empty (not exist).
This version improves compatibility with the SASL authentication method for some SMTP email providers.
Some bugs related to the service mode have been fixed. The new version of the software you can download in the Download area.
We've fixed a bug in ASTM parsers. You can download an update in the Download area.
We've fixed some UI glitches.
Added a possibility to control alarms from several data sources separately and filter out some events using an expression.
Added multi-line expressions and sending alarms via HTTP POST.
Now, you can extract data values using regular expressions.
It allows you, when you handle the "LOG-MESSAGE" event, extract the device address or ID and analyze and control events for various devices separately.
Improved performance of the OPC UA server.
Important if you have more than 100 tags. More on.
This update fixes some minor software bugs.
We've improved the HTTP POST export method.
Improved reading of user-defined or complex data types.
Fixed problem with reading data from ControlLogix 5500 @ Slot 1.
This update contains several improvements for UM31Smart and Mercury 230 power meters.
We've added MODBUS register maps for new energy meters.
Improved reading data from Logix5550 PLCs.
Improved handling of non-Latin characters in data while exporting data to Excel XLS.
Resolved a problem with deleting of widgets on a dashboard.
Now you can restrict access rights of some users.
We've improved the ASTM parser to handle large result sets.
Some user interface improvements and minor bug fixes.
Fixed problem with freezing when a response has been damaged.
Improved compatibility with InfluxDB v2 (added support for access tokens, more debug messages when writing fails).
We've added support for several new readers.
This release fixes a number of reported and internally discovered bugs.
Fixed a problem in the SQL Database Pro plugin that may cause the "Assertion failure" when data flow is too fast. Take a moment and then download it in the Download area.
T We've fixed a bug when the OPC DA server plugin didn't initialize OPC tags when DLS started by an OPC client. More on.
Improved an overall performance.
The previous version didn't save the page size in the settings for PDF files.
This version fixes a bug with icon list and improves the web interface for mobile devices.
The previous version deleted old log files after 10 days if you didn't specify another interval explicitly. The new version of the software you can download in the Download area.
We've resolved the problem with HTTP POST requests.
Added an option to enable a delay while exporting data from a MQTT data source. More on.
We've added TLS security connection settings and an option to customize a connection ID to the MQTT data source. Take a moment and then download it in the Download area.
We've added a possibility to redirect data to multiple data sources at the same time.
We've added support for TLSv11 and TLSv12 security protocols when sending emails and connecting to other public servers.
This release improves the MQTT data source plugin for a better compatibility with MQTT 3.1.1. Please, go to the download area and get an update.
We've added a possibility to specify a custom prefix for data values read from MQTT.
Previously, the program used a topic name as the prefix.
It can be too long or contain unwanted characters. Download.
The MQTT data source can automatically detect and decode JSON data in MQTT payloads. You can download an update in the Download area.
Now, the OPC server accepts reading for absent OPC tags but returns an empty value.
For example, after an OPC client launches the logger, but nothing is received yet. You can download an update in the Download area.
Several performance improvements in the SQL and OPC DA data sources. The new version of the software you can download in the Download area.
We've fixed a problem with unexpected crashes in configurations with multiple data sources (several IP or COM ports, for example). Please, go to the download area and get an update.
We've fixed a problem with SQL data sources.
The previous version may crash if two or more configuration with the SQL data source are created. Take a moment and then download it in the Download area.
You can find the update in the Download area.
We've added the SMS data source and several tutorials about SMS processing. The new version of the software you can download in the Download area.
We've added the SQL interface. The SQL data interface allows to poll a database table in SQL-compatible databases for new data and send the new data to other targets using data export plugins You can download an update in the Download area.
We've added the "File" interface type to our Advanced PBX Data Logger software.
It will allow to download call record databases from remote sites or some PBX through FTP, SFTP or FTPS protocols. Take a moment and then download it in the Download area.